Other

Formatting Process Of Mitsubishi Cnc Machine System

In the case of the original backup parameters of the machine tool manufacturer (or the system parameters backed up when the system is good)

  • 1. Shut down and disconnect the machine power
  • 2. Set RSW2 to C (RSW2 rotary switch is in the lower right corner of the controller)
  • 3. Press the emergency stop button to turn on
  • 4. After three minutes, shut down and disconnect the main power supply
  • 5. RSW2 is adjusted to 0
  • 6. Turn on in emergency stop
  • 7. Restore the original factory backup parameters to the machine tool
  • 8. With tool magazine, modify the PLC switch, check the tool change (spindle positioning angle, Z axis second origin position), and whether the machine origin is correct